The cost of energy is growing with enviable regularity, so whether you want it or not, you have to think about how to reduce the power of a gas boiler in order to save. Indeed, overpaying for "blue" fuel is impractical, unprofitable, and simply unreasonable. Do you agree?
Moreover, in many cases, saving gas, and with them, money is not difficult. And how to do this, read further in our publication.
The simplest ways to reduce power
The simplest and most effective, as well as operational methods that help save gas and reduce power include adjusting the boiler settings. Using them you can reduce consumption by a quarter.
These methods of reducing power include:
- adjust settings in manual mode;
- power adjustment in auto mode.
Both options can be used individually or in combination. That will help increase the energy efficiency of any heater to the optimum value.
A huge number of gas boilers are supplied to the market, but the principle of their operation is the same. As a result, the same reasons lead to an increase in energy consumption. And, accordingly, they can be eliminated by the same methods
Method # 1 - manual adjustment
This is the most inexpensive and fastest method of making adjustments to the operation mode of your gas boiler. Since the whole procedure resembles a decrease in the sound volume of the TV.
After all, all you need to do is perform 2 simple steps:
- Enter boiler service menu (not to be confused with regular custom). What happens after the introduction of a special code. You can learn it from the manufacturer, supplier, seller, in service centers and in many other ways;
- By pressing the “-” button set the desired power value.
An important advantage of the described method of reducing gas consumption is simplicity. Since almost any boiler user will be able to cope with the task. We recommend that you familiarize yourself with gas flow measurement methods.
The disadvantage is that when the boiler power is reduced, its efficiency decreases. As a result, if the adjustments are changed downward to a moderate value, this will be a reasonable compromise. Which will help to benefit from fuel economy.
Modern gas boilers are distinguished by their spectacular appearance, high efficiency and it is hard to believe that they, like 100 years ago, can be covered with soot and clog chimneys. But this is so, therefore, from the first day of operation, you need to tune in to the systemic care of the heating device. Otherwise, it will not please with moderate energy consumption, and in addition, the service life will be significantly reduced
In the same way eliminate impulse work boiler (its timing). Which is a common cause of excessive energy consumption.
At the same time, if you make an excessive decrease in the productivity of gas equipment (from maximum to minimum), the reduction in efficiency will be expressed in tens of percent of the optimal value. Which, again, will lead to additional and unnecessary costs.
Method # 2 - automatic adjustment
Cost-effective and efficient is the adjustment of the power of gas boilers using the so-called weather-dependent automation. Its feature is that the package includes external and internal temperature sensors.That is, when choosing the optimal operating mode, the indicators obtained during measurements on the street and inside heated rooms are taken into account, or rather compared,. That allows you to change the power of the boiler even before the air overheats in the rooms.
Example: with the onset of morning frost outside decreases, but at the initial stages of warming, internal sensors do not record temperature changes. Therefore, the boiler continues to operate with constant performance. But after a couple of hours this will lead to overheating of the indoor air, which means that part of the gas will be wasted.
A simple but effective way to change the power of any gas boiler is manual adjustment. Which will become available after entering the service menu. But still you need to understand that such a method is optimal for the so-called fine-tuning. If you do not observe the measure, then such a method may well lead to even greater gas overruns
At the same time, the use of an external temperature sensor will cause a temperature increase to be detected in a timely manner. This will allow to reduce the boiler power in advance. That is, it will not come to overheating the air. And this will provide a more economical gas consumption.
Manufacturers produce sets of weather-dependent automation for most of their modern boilers. But in most cases, it is not included in the basic package. That is, if necessary, the specified equipment will have to be bought.
Weather-dependent automation is not cheap, and therefore is an optional offer. Nevertheless, it is worth spending the required amount on a set of the specified equipment. But at the same time, it should be remembered that only certified equipment can be allowed to be used with the boiler
Both of the above adjustment methods are quite efficient. But you should be aware that the maximum benefit from them will only be if the gas boiler, as well as related equipment (for example, ventilation, smoke exhaust, etc.) is correctly selected, technically sound and works in the normal mode.
Otherwise, the use of adjustments will simply be a disguise for the existing problem. And to solve it, you have to look for other ways.
Effective methods to reduce gas consumption
There are a lot of reasons that significantly affect the decrease in the efficiency of gas boilers, and, accordingly, the increase in fuel consumption. Therefore, the user should initially identify one that adversely affects the performance of gas equipment. In order not to experiment, using the trial and error method to reduce power.
Moreover, often all that is needed to identify a problem that prevents the boiler from operating in optimal mode is to conduct a visual inspection of it. What can be done in a matter of minutes by either an employee of the gas service, a specialized company, or a person who owns only a basic set of specialized knowledge.
And after identifying the problem, you should choose one of the appropriate options for resolving it. Which we will consider in detail below.
Method # 1 - eliminating the causes of chemical underburning
Such important structural elements of any heating device as a heat exchanger, burner are often covered with soot, sintered dust and other types of pollution.
As a result, there is a decrease in the efficiency of heat transfer. Therefore, in order to reach the set temperatures, the gas boiler has to work for a longer time. Which leads to an increase in energy consumption.
If almost any user can cope with adjusting the boiler settings, then the rest of the work is not so simple. Actually, no one forbids them to perform independently, but you should remember about quality and safety
The reason for the clogging of the structural elements of the gas boiler is the burning of “blue” fuel.This phenomenon occurs when an insufficient amount of air enters the combustion chamber of the heater. The result of which is incomplete combustion of gas.
The problem is fixed in several stages:
- Carbon removal from heat exchanger surfaces, gas burner and other elements of the boiler design.
- Cleaning ventilation ducts. Moreover, this is a mandatory procedure. Since it is the inefficiency of the ventilation system that often leads to the fact that insufficient air is supplied to the gas burner.
- Cleaning the channels of the smoke exhaust system. This procedure is necessary due to the fact that the lack of oxygen can lead to inefficient removal of combustion products.
The specified manipulations can be performed by specialists of the gas service, specialized companies, as well as the owner of the boiler. But provided that he has sufficient knowledge and skills.
The photo shows soot in the chimney. The more it is, the less efficient any gas boiler becomes. Since a contaminated smoke exhaust system is always one of the main reasons for such a phenomenon as chemical underburning and subsequent energy overruns
If the structural elements of the boiler and air ducts are cleaned, and carbon deposits continue to form, and very quickly, then the problem with under-burns and inefficiencies can be solved with:
- commissioning;
- arrangement of ventilation systems, smoke removal.
Since commissioning is simpler and less expensive, you need to start with them. Why do you need to invite a gas specialist or a company that has the necessary license.
Arrangement of ventilation systems, smoke removal begins with the implementation of calculations. They make it possible to understand how much air is needed to eradicate such a phenomenon as under-burning, followed by excessive gas consumption.
For stable provision of the boiler with the required amount of air, it is better to use modern equipment (coaxial or sandwich ducts).
Method # 2 - eliminating the causes of mechanical underburning
This phenomenon occurs when part of the gas simply does not have time to burn out due to excess oxygen, while the surfaces of the boiler remain clean.
That is, the situation is the opposite of what happens with chemical underburning. And it is caused by the excessive performance of the smoke exhaust system, which leads to high traction. Which should be adjusted to eliminate the causes of incomplete combustion of "blue" fuel. What, with a traction limiter, can be done in seconds.
If the owners more or less successfully struggle with the problems that create dirty chimney ducts, then the same drawbacks of ventilation ducts are often forgotten. But they need to be cleaned, and regularly, if there is a desire to make your heater efficient
If the specified device is not provided, then using modern modular smoke removal systems, this drawback is easy to fix.
To solve problems with excessive traction, you can think about changing the type of smoke exhaust system, for example, to modern coaxial ducts with the desired diameter. This will be a practical solution - the optimal dimensions and the absence of a restrictor, which is a transverse partition, will make the air flow more stable. What will affect the quality of gas combustion.
In addition, the causes of mechanical underburning, and, consequently, gas overruns, can be:
- incorrect power setting;
- wrong choice of gas boiler for power.
In the first case, the problem can be eliminated by setting the heater in manual mode. How to do this is described at the beginning of the article.
Always remember that the boiler power settings are correct. Ignoring this warning may lead to impulse operation.And before solving the problem of economical gas consumption, you can not mention
Method # 3 - cleaning the heat exchanger and coolant
On the inner surfaces of the channels of the indicated structural element of the boiler, deposits are deposited consisting of ferric iron, salt deposits and other foreign particles. This can lead to the fact that in a few months from the start of operation, more heat will have to be spent to heat up the coolant to the desired temperature. To develop which you will need increased gas consumption.
When installing a gas boiler, you should take care of the correct commissioning. Since a poorly tuned fuel valve, nozzle or electronics will not give the expected result. Moreover, from the first day of using the heater, to eliminate this drawback, the internal cavity of the heat exchanger must be regularly cleaned.
What can be done in various ways:
- mechanical, i.e. manual cleaning;
- chemical, for which special solutions are used;
- hydrodynamicthat is carried out using ordinary water (under pressure).
Mechanical cleaning the heat exchanger is made using various brushes, scrapers. That is, with certain skills, this procedure will be able to be performed independently, although it is labor-intensive.
Chemical way cleaning consists in the fact that a special device called a booster is connected to the dismantled heat exchanger. And it repeatedly spills internal channels with special fluids (acids). Which cope even with the most resistant plaque.
Hydrodynamic way is the least labor intensive. Since all that is required when using it is to connect a special pump to the heating system. Then pure water is pumped into its channels, the pressure of which gradually increases. Which leads to stratification and subsequent removal of plaque.
The photo shows a dirty heat exchanger with a layer of soot consisting of gas combustion products and fused dust. Since this is the usual surface condition of any heat exchanger within a few months after use. And this should be remembered, because soot leads to a gradual decrease in heat transfer
The heat exchanger channels must be cleaned at least once every 2 years. To reduce the frequency of the specified procedure is possible only when using filters that are used to clean the coolant from all kinds of dirt particles. That allows you to clean the heat exchanger 2 times less often, that is, every 4 years.
To clean the coolant, you can use filters:
- rough cleaning;
- fine cleaning;
- magnetic.
All of these products can be used both together and separately. But the optimal combination of filters can be established only after laboratory analysis of water, which will be used as a coolant.
Method # 4 - reducing overall heat loss
If a gas boiler consumes gas disproportionately, but there are no external signs of a problem and it is correctly configured, then we can assume that the problem is not in the unit itself. And the blame for everything total heat lossto be eliminated. Otherwise, energy overruns cannot be avoided.
The arrows in the photo indicate the channels of the heat exchanger. As you can see, they are quite narrow, which is done to improve heat transfer. But this same feature leads to the fact that the channels are quickly clogged. What is the direct road to a significant increase in gas consumption
The causes of common heat loss are:
- improper installation of radiators;
- non-optimal total heat output of radiators;
- poor thermal insulation of doors, windows;
- lack of insulation of floors, roofs, walls of the building;
- insufficient insulation of ventilation ducts, smoke exhaust, others.
You should know that the efficiency of any gas boiler directly depends on the correct operation of the radiators. And the worst news is that to achieve a reduction in energy consumption by any manipulations with the heating boiler, with improper installation of radiators, it will not work.
Therefore, it is necessary to proceed to the indicated question as soon as it becomes clear that the boiler is serviceable and correctly configured.
When checking the correct installation of radiators, make sure that:
- Skewed. This is an important point, since the heatsink roll of more than 1 ° begins to affect the efficiency of the heating system. And significant inaccuracies made during the installation of several products will lead to a significant loss of efficiency, and by tens of percent;
- Batteries are located in places where the heat loss is usually greatest. (for example, at windows). And placed 12 cm from the floor, 2 cm from the wall and 10 cm from the windowsill, which should overlap the radiator by 2/3.
And also you should pay attention to the absence of excessive bends in the places where the pipes turn, through which the coolant enters, the correct installation of the air vent valves.
Cleaning the heat exchanger channels with acids, although it requires a special device (booster), is less labor-intensive than the same manual procedure. In addition, better. And most importantly, there is less chance of damaging the design of the product
As already indicated, the total thermal power of the radiators and the gas boiler used should be approximately equal.
If this rule is not observed, then at a low total power the gas boiler will heat the coolant to critical 75 ° C. At which quick wear of all the structural elements of the heating system made of polymer plastics will begin. What threatens leaks.
In addition, at this temperature, dust particles massively burn out, which does not contribute to the comfort of living.
And the worst thing is that the difference in the performance of the equipment that is used as part of the heating system will lead to clocking (frequent on / off). At which a considerable part of the gas will simply fly out into the pipe without burning. The reason is that the electronics of all boilers are programmed so that gas is supplied first, and after some time a spark is produced.
The main reason for the inefficiency of boilers is traditionally the general heat loss. That is, without the elimination of heat loss, there can be no question of any reduction in gas consumption
In addition, when turned on, the performance of gas boilers traditionally reaches peak values, which is designed to eliminate problems during their ignition. And this feature with frequent launches leads to even greater losses.
It should be remembered that the efficient operation of gas boilers in a room equipped with windows, doors with cracks, cracks and not insulated walls, floors, ceilings cannot be. That is, the listed disadvantages should also be eliminated.
The importance of boiler maintenance
Effective methods that allow solving such a problem as reducing gas consumption by a boiler were listed above. But they all have an unpleasant feature. The reason is that the procedures described are used when the heating unit, and with it the entire heating system, has become less effective. Which leads to increased fuel (gas) consumption and reduced living comfort.
And such a disadvantage can be eliminated only with the help of maintenance. The main feature of which is the ability to prevent an increase in gas consumption, as well as prevent premature wear of structural elements of any gas boiler. That allows you to save even more.
You should not reduce gas consumption using illegal methods.Since, as a punishment, you can get a fine of up to a million rubles and with a possible restriction of freedom (Article 158 of the Criminal Code). And this, if there are no consequences in the form of harm to health, the life of other people
The specified procedure is a complex of various works, namely:
- control;
- verification.
Which allow you to timely identify signs of all problems leading to a decrease in boiler efficiency. The exception is only the clogging of the heat exchanger channels, since it cannot be visually detected. Therefore, in this case, you just need to combine cleaning work with maintenance (with the right frequency).
Maintenance must be performed at least once a year before the start of the heating season. But it is more practical to carry out maintenance up to 3 times for every 12 months:
- before seasonal operation;
- during its operation;
- after the end of the heating season.
An important advantage of boiler maintenance is that its owner can carry out a significant part of the work. Since all that is needed for this is to have a certain set of knowledge and practical experience.
The first video material will allow you to better understand the reasons that lead to an excessive energy consumption by the boiler.
The next video talks about how to reduce the consumption of "blue" fuel to a minimum.
It is quite realistic to reduce gas consumption by a domestic boiler, and in many cases this can be done quickly and without financial costs. But it should be remembered that the most effective method is regular maintenance.
In addition, when performing any work on gas equipment, one should not forget about safety measures.
Do you want to supplement our material with useful comments or tell your secrets to reduce gas consumption? Or do you have questions about reducing fuel consumption by a gas boiler? Add your comments, ask for advice from our experts and other visitors to the site - the feedback block is located below the article.