Electricity supply systems with the simultaneous use of the traditional supply of current and electricity from the sun are an economically viable solution for private households, cottage, summer cottages and industrial premises.
An indispensable element of the complex is a hybrid inverter for solar panels, which determines the modes of voltage supply, ensuring uninterrupted operation and the efficiency of the solar system.
For the system to work efficiently, you need not only to choose the optimal model, but also to connect it correctly. And how to do this - we will analyze in our article. Also consider the existing types of converters and the best deals on the market today.
Hybrid Inverter Capability Assessment
Using renewable solar energy in combination with a centralized power supply offers several advantages. The normal functioning of the solar system is ensured by the coordinated operation of its main models: solar panels, charge controller, battery, and also one of the key elements - the inverter.
Solar system inverter - a device for converting direct current (DC) from photovoltaic panels into alternating electricity. It is at a current voltage of 220 V that household appliances work. Without an inverter, generating energy is pointless.
The scheme of the system: 1 - solar modules, 2 - charge controller, 3 - battery, 4 - voltage converter (inverter) with AC supply (AC)
It is better to assess the capabilities of the hybrid model in comparison with the features of the work of its closest competitors - autonomous and network "converters".
Converter type network
The device operates on a shared mains load. The output from the converter is connected to consumers of electricity, AC network.
The scheme is simple, but has several limitations:
- operability at availability of alternating current in a network;
- mains voltage must be relatively stable and consistent with the operating range of the converter.
The variety is in demand in private homes with the current "green" tariff for electrification.
During the day, with minimal energy consumption, the generated current is supplied to the network at “green” prices, from evening until morning the building is “energized” by a centralized electricity supply
Standalone version of the device
The device is powered by a battery that receives charge from the solar panels through an MRPT controller. The system uses different types of batteries, including high-tech lithium batteries.
At the maximum “filling” of the storage device, excess electricity is transmitted to the inverter input, the output of which is connected to the end users of the AC.
In the event of a lack of solar activity, energy is taken from the storage batteries and passes “conversion” through the voltage inverter.
Features of the autonomous installation:
- the possibility of independent operation in the absence of AC power;
- some models support the mode of operation at the “green” tariff;
- The efficiency of the installations is 90-93%.
To ensure the absolute autonomy of the object, an accurate calculation of the power of solar panels and sufficient energy consumption of the battery are required.
The option of independent use of the inverter without including a centralized network connection in the system. Stand-alone converter is in demand in areas with a complete lack or low quality of electricity supply
Hybrid Inverter Type
The model differs from the devices described above in a special “architecture” of manufacture. A special electrical circuit is provided inside, which allows in parallel operation with the current source (mains, generator) in the converter mode.
At the same time, the load is supplied by the central network and solar panels, while the priority function is assigned to the DC supplier.
The hybrid converter allows you to consume solar energy as efficiently as possible without switching from the power supply network from a central station or generator
Competitive advantages lie in the multifunctionality of hybrid inverters:
- Net - A kind of roomy battery with an efficiency of 100%. All surpluses generated by photovoltaic plates can be redirected to the central network at a “green” tariff.
- Uninterruptible Power Supply. When you turn off the main power supply, the system is rebuilt into offline mode, protecting all consumers from voltage surges.
- Increased network capacity limit during peak loads due to the addition of energy from the battery-inverter complex.
With a decline in consumption, the solar complex switches to charging mode and is ready for use again after a while. Double power function can be indicated: Smart Boots, Power Shaving, Grid support.
Image Gallery
Photo from
The work of hybrid inverters is to convert the DC energy generated by the photocells of the battery into alternating current suitable for powering standard household appliances
A feature of the hybrid inverter is the presence of an integrated controller that prevents equipment overheating
The hybrid inverter can operate in parallel with electrical sources with alternating current sources - a generator or a centralized network. In doing so, it will act like a normal inverter
Among the hybrid inverters there are models whose power can be added to the power of the network. This function is needed if the power of the power line is not enough to develop peak load.
In most cases, a single-phase hybrid inverter is sufficient to convert the energy generated by private mini-power plants. For public and industrial facilities, it is better to purchase a three-phase
In case of insignificant receipt of energy from solar panels, batteries are charged from the network. If the power consumption from the network is too large, add batteries or buy a Powerwall with a built-in inverter in addition
The location of the equipment necessary for the operation of a solar power station in one building allows compact and convenient arrangement of devices. The hybrid inverter provides the ability to more flexibly tune to the current intake from solar panels or from the network
The hybrid inverter LCD displays the operating parameters. When connected to a PC, almost all new devices can send data to the owner or store them in the cloud for reporting to the manufacturer
Hybrid Inverter Models
A complex of equipment for solar panels
Hybrid Inverter Connection Option
Getting AC power
Three-phase and single-phase equipment
Li-ion battery with integrated inverter
Equipment for flexible consumption settings
Display of operating parameters on the screen
The addition of power occurs according to the following principles:
- if the used power is lower than the maximum network consumption, then in addition to the load power, the accumulator battery is charged;
- in the absence of voltage in the network, energy is consumed from the battery and converted by the inverter;
- if the load exceeds the limit value of the network power, then the deficiency is compensated for by the accumulated electricity from the solar battery.
The listed operating modes are capable of supporting hybrid models with a charger.
Some multifunction inverters are designed to simultaneously connect multiple AC lines to automatically enter the reserve. High-tech models independently regulate the battery charge
Varieties of current converters
Choosing the "heart" of an autonomous power supply system, it is necessary to correctly correlate the tasks assigned to the equipment with its potential capabilities.
The main features of the classification of hybrid inverters are: an algorithm for changing operating modes, the shape of the output voltage and the ability to service a single or three-phase network.
Comparison of UPS and Hybrid Installation
Some companies inadvertently mislead the consumer, calling the uninterruptible power supply unit (UPS) a hybrid inverter. It would seem that both devices perform similar tasks, but there is a significant difference.
BBP is an inverter with a charger. The module primarily provides energy consumption from a photovoltaic installation, and if it is deficient, it switches to consumption from the network.
BBP is not able to perform the function of “mixing” the accumulated electricity from the batteries with the mains. Priority consumption from a DC source is realized by disconnecting from the network and switching to battery operation
The functioning of the system in “jerking” mode provokes additional cycling of the battery and accelerates its wear. In most inexpensive power supply systems, the threshold voltage is set without regulation.
In the models of hybrid inverters for solar batteries, such surges are excluded - the unit adjusts to the required power and works simultaneously with different current sources.
You can choose priority consumption yourself. As a rule, the emphasis is on the use of energy from solar panels. Some hybrid units have the option of limiting the power coming from the city network.
Comparison of functions of popular modifications of hybrid “converters” and BBP. In the Victron series of models, it is possible to increase inverter power due to network
Varieties of the inverter waveform
Solar current converters are classified by the type of output signal.
Distinguish:
- pure sine wave;
- modified sine (quasi-sine wave);
- meander.
The latter option is practically not used in practice, since a sharp change in polarity causes equipment malfunctions.
An inverter with a “U-shaped” signal will not be able to protect devices from voltage surges. In addition, the main part of household appliances does not perceive the meander current
What is a pure sine wave?
The converter produces a high-quality signal that exceeds the shape of the mains current. This is the best option for the operation of “sensitive” equipment: heating boilers, compressors, electric motors, medical equipment and devices based on transformer power supplies.
Disadvantages of sine wave inverters: high cost and large dimensions. Buying a pure sine transducer will cost twice as much as a quasi-sine wave model with equal total power
Quasi-sine features
Energy signal transmission in the form of a modified sine wave can reduce the efficiency of some devices, provoke the appearance of noise, cause interference or damage equipment.
When powered by low-frequency transformers, asynchronous, synchronous motors, a power loss of 20-30% is visible. This "defect" is converted into thermal energy, overheating appliances.
Pseudo-sine wave inverters are compact and affordable. Their use is advisable for powering devices without inductive loads, designed for the consumption of active components of electric power.
This group includes: thermoelectric heaters, incandescent lighting systems and other resistive structures.
Options for the modified sine: 1 - a complicated form of a meander with a pause, 2 - approximation to a pure sine due to an increase in the number of transitions
The shape of the output signal is indicated in the passport of the inverter or uninterruptible. Possible notation: “Back” - a guarantee of the absence of a pure sine, “Smart” - the probability of obtaining a high-quality current at the output.
Some manufacturers in the accompanying document note the harmonic coefficient (index of nonlinear distortion). If the parameter is less than 8%, then the unit produces an almost perfect sine.
Single phase and three phase models
Single-phase inverters are mainly built into the circuit of a domestic photovoltaic system with a standard voltage of 220V.
The output voltage range when connected to one phase in different models ranges from 210-240V, the output frequency is 47-55 Hz, the power is 300-5000 watts.
Single-phase inverters are available under standard battery voltage values: 12, 24 and 48 V. In order for the converter to not function at the limit of capabilities, it is necessary to coordinate the power of the “converter” with the voltage of the solar battery or battery.
The range of dependence of the characteristics of the battery (voltage - V) and the solar converter (rated power - W): 12 V - within 600 W, 24 V - up to 1.5 kW, 48 V - over 1.5 kW
Three-phase inverters are used to supply three-phase current, providing power to electric motors. Primary application - production, workshops, commercial use.
Inverters for three phases are characterized by high power (3-30 kW), a wide range of output AC voltage (220V / 400V).
Combined models are also on the market. These include single-phase inverters with the ability to synchronize the converter outputs with a phase shift - this allows you to power three-phase loads. All types of techniques for converting current from solar panels, we examined in another of our article.
Solar Inverter Selection Parameters
The efficiency of the converter and the entire power supply system largely depends on a competent choice of equipment parameters.
In addition to the above characteristics, you should evaluate:
- output power;
- type of protection;
- working temperature;
- installation dimensions;
- Efficiency
- availability of additional features.
Further we consider all these characteristics in more detail.
Criterion # 1 - device power
The rating of the “solar” inverter is selected based on the calculation of the maximum load on the network and the estimated battery life. In start-up mode, the converter is able to give a short-term increase in power at the time of commissioning of capacitive loads.
This period is typical when you turn on dishwashers, washing machines or refrigerators.
When using lighting lamps and a TV, a low-power inverter for 500-1000 watts is suitable. As a rule, the calculation of the total power of the operated equipment is required. The desired value is indicated directly on the device body or in the accompanying document.
It is desirable to increase the obtained value by 20-30% - this will be the required output power of the inverter. For example, the total power of the equipment is 500 W / h, the battery life is 5 hours. Calculation: 500 W / h * 5h * 1.2 = 3000 W / h
Criterion # 2 - protection level
A high-quality solar inverter must have several levels of protection. Possible options: forced cooling system, short circuit warning, protection against voltage dips and surges.
It is important - the presence of a sealed fortified housing that prevents dust, moisture from entering the inside. The electrical protection rating is standardized according to IEC-952 standardization.
The index is designated as IP AB, where A is the level of protection against the penetration of foreign particles into the device, B is the resistance to moisture
For outdoor operating conditions, models with the IP65 index are suitable - the strength and reliability of the inverter allows its use in an external atmosphere.
Criterion # 3 - operating temperature and dimensions
A wide range of values is an indicator of a decent build quality of the inverter. The value of the indicator is especially relevant when placing the converter in an unheated room.
Weight is an indirect indicator of the quality of the inverter. There is an opinion - the heavier the converter, the more powerful it is. This is due to the presence of a transformer in high-power equipment.
In "lightweight" models, the absence of a transformer can cause inverter failure when a high inrush current is applied.
According to observations, one kilogram of the weight of the solar converter corresponds to an output power of 100 watts. The dimensions of the inverter determine the method of its installation
Criterion # 4 - coefficient of performance
Experts recommend purchasing current “converters” with an efficiency of 90%. Only with such a parameter will the work of the solar system be effective, and its arrangement expedient. The loss of 10% of solar energy is an unacceptable "luxury".
Additional functionality. Advanced features affect the cost of equipment and are not always in demand. However, some options justify the money spent.
Useful and necessary “devices” include:
- automatic addition of inverter power to the grid electricity;
- adjustment of the battery charging period;
- selection of priority current source;
- maintenance of work with different types of batteries (alkaline, lithium iron phosphate, helium, AGM, acid);
- the possibility of combined work with a network converter;
- setting the voltage indicator - warning of “surges” in mains voltage;
- the ability to upgrade the inverter by updating the firmware.
Modern converters can be connected to a PC for programming and monitoring.
To track the operation of equipment and power networks, manufacturers offer free software. An interesting option is the ability to send SMS alerts about the status of the system at the request of the user
Overview of Popular Hybrid Converters
Inverters from foreign companies received good reviews among consumers: Xtender (Switzerland), Prosolar (China), Victor Energy (Netherlands), SMA (Germany) and Xantrex (Canada). Domestic representative - MAP Sine.
Xtender Multifunction Inverter Line
Xtender's Studer Hybrid Converter is the epitome of the Swiss quality standard in power electronics. Xtender Series Solar Inverters are distinguished by their indicative strength characteristics and extensive functionality.
A variety of models: ХТS - low-power representatives, ХТМ - medium power models, ХТН - high-power inverters.
Xtender power ranges: ХТS - 0.9-1.4 kW, ХТМ - 1.5-4 kW, ХТН - 3-8 kW. Output voltage - 230 W, frequency - 50 Hz
Each Xtender Hybrid Drive Series has the following features and options:
- pure sine wave feed;
- "Mix" of power to the network from the battery;
- when the mains voltage decreases, the consumption from the central power supply decreases;
- two priority selection modes: the first is “soft” with recharge from the network within 10%, the second is full switching to the battery;
- variety of installer settings;
- backup generator control;
- standby mode with a wide range of regulation;
- remote monitoring of system parameters.
In all versions there is a Smart Boost function - connection to different “suppliers” of power (generator set, network inverter) and Power Shaving - guaranteed coverage of peak loads.
Optimum Prosolar Hybrid Converters
The Chinese-made model has good characteristics and an acceptable cost (about 1200 cu). The inverter optimizes the performance of solar panels by storing unspent energy in the battery.
Specifications: voltage shape - sinusoid, conversion efficiency - 90%, installation weight - 15.5 kg, permissible humidity - 90% without condensation, temperature -25 ° С - +60 ° С
Distinctive features:
- option for tracking the limit point of the solar battery;
- Information LCD display with the display of the operating parameters of the system;
- 3-level battery charger;
- adjustment of the maximum current to 25A;
- communicator inverter.
The converter is connected to the PC via software (supplied as a kit). It is possible to upgrade the inverter through innovative flashing.
Sine Wave Inverters Phoenix Inverter
Phoenix inverters meet the highest demands and are suitable for industrial applications. The Phoenix Inverter series is released without a built-in charger.
The converters are equipped with a VE.Bus information bus and can be used in parallel or three-phase configurations.
The power range of the model range is 1.2-5 kW, the efficiency is 95%, the voltage type is a sinusoid.
The table shows the characteristics of the hybrid modification of the 48/5000 inverter from Victron Energy. Estimated cost of Phoenix Inverter with a power of 5 kW - 2500 cu
Competitive advantages:
- SinusMax technology supports the launch of “heavy loads”;
- two modes of energy conservation - the option of finding the load and lowering the no-load current;
- presence of an alarm relay - warning of overheating, insufficient battery voltage, etc .;
- setting programmable parameters via PC.
To achieve high power, up to six converters can be connected in phase in parallel. For example, a combination of six devices with a nominal value of 48/5000 can provide an output power of 48kW / 30kVA.
Domestic devices MAP Gibrid and Dominator
The company MAP "Energy" has developed two modifications of the hybrid converter: Gibrid and Dominator.
The range of equipment capacities is 1.3–20 kW, the time interval for switching between modes is up to 4 ms, the possibility of “pumping” electricity into the city network is provided.
Comparison table of transducer capabilities. Both types are able to work in ECO mode, each model is “connected” with a Web server for remote monitoring and adjustment
General characteristics of Gibrid and Dominator voltage converters:
- torus-based transformer;
- input voltage stabilization is absent;
- power swap mode;
- output - pure sine;
- generating an excess of energy in the network;
- limitation of current consumption at the input of the speaker;
- class IP21;
- consumption in "sleep" mode - 2-5W.
The efficiency of converters reaches 93-96%. The devices have successfully passed tests for use at extremely low temperatures (limit value -25 °, a short-term reduction to -50 ° C is permissible).
Possible connection schemes
When constructing a photovoltaic complex combined with a central network, there are different options for connecting an inverter.
Option # 1 - circuit with DC charge controller
The most popular option is where the battery is charged through the MPPT solar controller (peak power point analysis).
The circuit uses a converter that supports the transmission of electricity to the network or to the load if the battery voltage exceeds a user-specified parameter
Features of the solution:
- efficient use of renewable energy in the presence / disconnection of the network;
- the ability to activate work from the solar system after the battery is discharged.
And also another solution is a slightly increased loss of energy conversion at the controller-battery-inverter section.
Option # 2 - circuit with a hybrid and network converter
Line converter at the output of the battery inverter. According to the scheme, two converters are connected to different solar panels.
The hybrid converter is connected to the optional photovoltaic panel to recharge the battery, the network is connected to the main solar module.
Under normal conditions (presence of mains current), the line converter supplies the redundant load, the conversion efficiency is about 95%. Excess energy is supplied to the battery, and when it is filled, to the common network
System Features:
- uninterrupted operation regardless of the presence of central mains voltage;
- high efficiency and minimization of losses on the DC side due to the sufficient voltage level of the solar battery;
- batteries almost always operate in a buffer mode, which increases their service life;
- the use of hybrid inverters designed to charge the battery from the output;
- the need to adjust the operation of the network inverter.
The total power of the network converter should not exceed the power of the hybrid "converter" - this allows you to utilize the energy of solar panels in the event of a battery discharge, disconnecting the network.
Regardless of the selected circuit, when connecting an inverter, a number of nuances should be taken into account:
- Wired connections for DC should not be long. It is advisable to place the inverter in the vicinity (up to 3 m) from the solar panels, and then “build up” the trunk with AC.
- The transmitter must not be mounted on a combustible structure.
- The wall inverter is located at eye level for easy reading of information from the display.
By connecting models with a power of more than 500 watts, special requirements are made. The connection must be rigid with a reliable contact between the terminals of the device and the wires.
Also on our site there are other articles on solar energy and the connection of individual components and modules during the assembly of an autonomous system.
We recommend you familiarize yourself with the following materials:
- Connection diagram for solar panels: to the controller, to the battery and to the serviced systems
- Solar-powered charger: device and principle of operation of charging from the sun
- How to make a solar battery with your own hands: methods of assembly and installation of a solar panel
The concept of "hybrid inverter", its device, functions and options:
Overview of the features, operating modes and efficiency of using the 3 kW InfiniSolar multifunction converter:
Designing a solar power system is a complex and demanding task. Calculation of the necessary parameters, the selection of the components of the heliocomplex, connection and commissioning is best left to professionals.
Mistakes made can lead to system failures and inefficient use of expensive equipment.
Choosing the best converter option for the operation of an autonomous solar energy power supply system? Do you have questions that we did not address in this article? Ask them in the comments below - we will try to help you.
Or maybe you noticed inaccuracies or inconsistencies in the material presented? Or do you want to supplement the theory with practical recommendations based on personal experience? Write to us about this, share your opinion.